|
|
|||||||||||
|
PART NUMBER:48-3358 |
||||||||||
| INDICATED USE: General purpose survey, gross counting COMPATIBLE DETECTORS: G-M, proportional, scintillation CONTROL SWITCH: A 5 position rotating switch to allow for quick change among 3 external detectors or the internal G-M. INTERNAL DETECTOR: Energy compensated G-M INTERNAL DETECTOR LINEAR RANGE: 1mR/hr to 10 R/hr ALERT/ALARM: Indicated by annunciator on display and audible tone DISPLAY: 4 digit LCD display with 0.5"(1.3cm) high digits, separate annunciators for display units, alert, alarm, low battery, detector overload, counting overflow, and scaler counting BACKLIGHT: Push-button to activate RATEMETER: Can display in R/hr, Sv/hr, cpm, or cps when control switch is in RATEMETER position DISPLAY RANGE: Auto ranging from 0.0 µR/hr - 9999 R/hr; 0.000 µSv/hr - 9999 Sv/hr; 0.00 cpm - 999k cpm; or 0.00 cps - 100k cps SCALER: Activated by push-button in handle (count time adjustable from 1 - 9999 seconds in 1 second intervals) HIGH VOLTAGE: Four independent controls; each adjustable from 200 - 2500 volts DISCRIMINATOR: Adjustable from 2 - 100 mV OVERLOAD: Indicated by OVERLOAD on display (adjustable depending on detector selected) BATTERY LIFE: Typically 200 hours with alkaline batteries (24 hours when low battery is first indicated on display) SIZE: 6.5"(16.5cm)H X 3.5"(8.9cm)W X 8.5"(21.6cm)L WEIGHT: 3.5 lbs (1.6kg) including batteries The following parameters are adjusted for each detector by removable switchboard. Once initial setup and calibration have been completed the switchboard can be removed without affecting normal operation of the instrument (Model 2241-3i may be ordered without switchboard) BACKLIGHT "ON" TIME: 5, 30, 60, 90, 180, or 240 seconds for the backlight to stay "ON" when activated. SET MINIMUM DISPLAY: Allows lower limit of auto-ranging display to be fixed. For example, display can be set to not show values less than 1 R/hr. RS-232 DATA DUMP MODE: Enables or disables dump mode to RS-232 port. When enabled data will be dumped every 2 seconds RS-232 DETECTOR SETUP MODE: Allows for detector parameters to be input by RS- 232 port BAUD RATE: 150, 300, 600, 1200, 2400, 4800, 9600, or 19200 bps. DEAD TIME: Adjustable from 0 - 9999 seconds CALIBRATION CONSTANT: Adjustable from 0.001 - 280 X 109 counts/display unit DISPLAY UNITS: Can read in R/hr, Sv/hr, cpm, or cps TIME BASE: Can read in seconds or minutes AUDIO DIVIDE: 1, 10, 100, or 1000 events-per-click RESPONSE: FIXED: FAST response time adjustable from approximately 2 - 50 seconds. SLOW response is 5 times fast setting VARIABLE: Dependent on number of counts present. Typical times FAST - 4 - 25 seconds, SLOW - 4-60 seconds (All times stated from 10% to 90% of final reading) RATEMETER ALERT/ALARM: Set at any point corresponding to pre-selected ratemeter range SCALER ALARM: Adjustable from 1 - 999999 counts SCALER COUNT TIME: Adjustable from 1 - 9999 seconds |
|||||||||||
|
|
|||||||||||
|
|||||||||||
|
|
|||||||||||
|
Model 2241 Series Digital Display |
|||||||||||
|
|
|||||||||||
|
|
|||||||||||
|
|
|||||||||||
|
|
|||||||||||
| Ordering Info. | |||||||||||
|
|
|||||||||||
Copyright © 2000 Ludlum Measurements, Inc. For comments or suggestions please contact webmaster at: ludlum@ludlums.com Page last updated: December 2006 |
|||||||||||