Part Number - 48-2410 |
| INDICATED USE: Area monitoring DETECTOR: Geiger-Mueller RANGE: 0.1 mR/hr - 1 R/hr DISPLAY: 4 digit LED display with 0.8"(2cm) character height DISPLAY RANGE: 000.0 - 9999 DISPLAY UNITS: Can be made to display in microR/hr, mR/hr, R/hr, microSv/h, mSv/h, Sv/h, cpm, cps, and others LINEARITY: Reading within plus or minus 10% of true value RESPONSE: Typically 3 seconds from 10% to 90% of final reading STATUS: (green light) Indicates the instrument is functioning properly LOW ALARM: Indicated by a yellow light and slow beep (1 per second) audible tone (can be set at any point from 0.0 - 9999) HIGH ALARM: Indicated by a red light and fast beep (4 per second) audible tone (can be set at any point from 0.0 - 9999) NOTE:Audible indicators can be configured as a single beep if desired. DET FAIL: (red light and audible tone; greater than 68 Db at 2 feet) Indicates detector overload, no count from detector, or instrument failure LOW BAT: (yellow) Indicates less than 2 hours of battery power remaining CONNECTOR: Series "C" (others available ) CALIBRATION CONTROLS: Accessible from front of instrument (protective cover provided ) HIGH VOLTAGE: Adjustable from 200 - 2500 volts THRESHOLD: Adjustable from 2 - 100 mV DEAD TIME: Adjustable to compensate for dead time of the detector and electronics (can be read on the display) OVERLOAD: Senses detector saturation (indicated by display reading"-OL-") OVERRANGE: Indicates the radiation field being measured has exceeded the counting range of the instrument (indicated by display reading "----") DATA OUTPUT: 9 pin connector providing 5 decade log output, RS-232 output, signal ground connection, FAIL and Alarm signals (current sink), and direct connection to battery and ground REMOTE(optional): Model 271, or Model 272 remote units POWER: 95 - 135 VAC (178 - 240 VAC available), 50 - 60 Hz single phase (less than 100 mA), 6 volt sealed lead acid rechargeable battery (built in) BATTERY LIFE: Typically 48 hours in non-alarm condition, 12 hours in alarm condition BATTERY CHARGER: Battery is continuously trickle charged when instrument is connected to line power and turned on CONSTRUCTION: Aluminum housing with ivory polyurethane enamel paint TEMPERATURE RANGE: -4° F(-20° C) to 122° F(50° C) May be certified for operation from -40° F(-40° C) to 150° F(65° C) SIZE: 7.4" (18.7 cm)H X 9.7" (24.6 cm)W X 2.5" (6.4 cm)L WEIGHT: 6.5 lbs (2.3 kg) |
|
|
|
|
|
OPTIONAL ACCESSORIES |
|
|
|
|
| Ordering Info. Manual Technical Info. | |
|
|
|
Copyright © 2001 Ludlum Measurements, Inc. For comments or suggestions please contact webmaster at: email Mick Truitt Page last updated: May 19, 2001 |
|